During the first 15 minutes of a website outage, confirm customer impact from another network, appoint an incident owner and test DNS, TCP, TLS and HTTP in that order. Preserve the original alert before changes and post a factual first update. The enterno.io command output below is a healthy baseline, not a reconstructed production outage.

“The site is down” can mean a stale DNS answer, an unreachable port, a certificate failure, HTTP 503 or a 200 response containing a blank page. Restarting the application before identifying the layer can erase useful evidence. Google SRE's incident framework separates coordination, operations and communication. Small teams may combine roles, but the people holding them should still be named.
Minutes 0–3: confirm impact and preserve evidence
Capture the UTC alert time, exact URL, check type, probe region and error. Repeat the user action from an independent network or use an external enterno check. If only one region fails, follow the regional investigation before calling it global downtime. Test the failed action, not merely the homepage. Note recent deploys and config changes, but do not roll one back until its symptoms match a plausible cause.

Minutes 3–8: identify the failing layer
From an external host, check the address, handshake and response. `dig` reports one DNS answer; it does not prove the authoritative zone is healthy. The DNS guide shows how to compare resolvers. `openssl s_client` tests SNI and the certificate path. `curl` records status and connection timing. Compare the result with a known healthy baseline and another network. A direct TCP connection check may be useful if TLS never starts.
dig +short enterno.io A
81.163.20.249
openssl s_client -connect enterno.io:443 -servername enterno.io -brief
Protocol version: TLSv1.3
Verification: OK
curl -L -sS -o /dev/null -w 'http=%{http_code} connect=%{time_connect} tls=%{time_appconnect} total=%{time_total}\n' https://enterno.io/
http=200 connect=0.037281 tls=0.087791 total=0.270954
These are measured results from a healthy public site on November 14, not outage evidence. `data.json` includes the destination IP and negotiated cipher. If DNS differs, inspect delegation and another resolver. If port 443 times out, check edge routing, firewall and origin connectivity. For TLS errors, inspect SNI and chain with the s_client guide. For 5xx, identify which hop sent the response using the HTTP error guide. If 200 contains a broken page, use a content marker.
| Observation | Next check | Avoid for now |
|---|---|---|
| Wrong DNS address | Authoritative NS, TTL, second resolver | Restarting PHP |
| No TCP on 443 | Route, load balancer, firewall, origin | Replacing the certificate |
| TLS fails | SNI, chain, expiration | Blaming the backend |
| HTTP 5xx | CDN, proxy and application logs | Muting every alert |
Minutes 8–15: choose one action and communicate
Give one person ownership of changes. If a recent deploy matches the evidence, prepare a reversible rollback and verify the affected user action afterwards. If data integrity is at risk, stop unsafe writes before routine restarts. The escalation policy names backup responders; the SEV matrix determines response breadth. A communications owner posts an initial update with confirmed impact, current investigation and next update time.
The 0–3, 3–8 and 8–15 minute bands organize a first cycle; they do not promise that every outage is repaired in a quarter hour. At minute 15, update the owner, working hypothesis and next communication time. Do not close the incident because one HTTP request turns green. Retest the action customers could not complete and watch an independent signal.
Distinguish reachability from a failed user action
“Does the site load?” is too broad. The homepage may return 200 while login, form submission or checkout fails. Exercise the route named in the report or alert. For an authenticated feature, use a limited test account rather than a customer's private token. If the check writes data or submits a payment, design its cleanup and duplicate protection before running it. Do not stage a live financial transaction without controlling its consequences.
Latency matters as well. A request that eventually returns 200 after 45 seconds may already have lost its user. The sample `curl` output reports connection, TLS and total time from one host; it is not a customer p95 measurement. Use real traffic metrics or independent probes to estimate reach. If only one provider or geography fails, keep that route as distinct evidence rather than averaging it away.
Find which hop produced the error
For 5xx, inspect the response and logs at CDN, edge proxy, load balancer, origin and application. A code shown in the browser does not identify the failing component by itself. If the origin has no matching request, the request may not have reached it; the log may also be filtered. Do not assign a root cause without matching timestamps and a request identifier. In an earlier enterno review, a cloud-facing 502 lacked a match in a filtered Traefik log. That is an observation limit, not proof of a specific connection bug.
Look for recent DNS, certificate and CDN changes. If none match the symptom, a blind rollback of the latest commit is not justified. If a deploy matches both time and behavior, choose the smallest reversible action and define how success will be measured. Database schema changes need a separate data-integrity check; a code rollback does not automatically reverse a migration safely.
Communicate while diagnosis continues
One responder can isolate the layer while another measures impact and drafts a public update. With fewer people, the incident lead should set the next communication time so log inspection does not crowd out customer information. A first notice can name the failed feature and current investigation. Say that reach is still being measured when it is. A repair ETA without a tested recovery plan creates a second failure of trust.
Support needs the same factual status as the public page plus a route for escalating customer reports. Do not tell someone to retry a payment until you know whether the first attempt was captured; that can create duplicate charges. Name a person to reconcile transactions after recovery. Keep timestamps for updates and changes in working theory for the postmortem.
Verify recovery from more than one signal
After a fix, repeat the originally failing action from the affected regions. Check the fresh HTTP result, body and latency, then watch application error rates. One green monitor check may be a brief success between failures. Choose an observation period based on traffic volume and failure mode. For a low-traffic path, an hour without errors proves little if nobody attempted the action.
At closure, record measured start and end of customer impact, the confirmed cause or remaining uncertainty, the change made and any residual risk. Remove temporary bypasses that weaken security or hide future alerts. Write a short follow-up: which signal found the fault, where response stalled and what monitor or runbook change is needed. That turns the first 15 minutes into an improving procedure instead of an improvisation.
How we made this runbook
`method.py` ran read-only `dig`, `openssl s_client` and `curl` against the public enterno.io endpoint. The output showed A 81.163.20.249, verified TLS 1.3 and HTTP 200 with a 0.270954-second total on one host. These are baseline measurements, not a real outage timeline. The first brief requested a production incident chronology; we cannot substantiate one from the available evidence and do not present an invented event. SerpAPI snapshots cover Google US and Yandex Moscow. Wordstat region 225 estimated 23 searches for the narrow Russian query and 254 for a broader wording.
FAQ
What if the site fails only on my connection?
Repeat the same URL from another network and compare DNS answers before calling it a global outage.
Should we restart the server immediately?
Identify the failing layer and preserve evidence first; a restart may obscure the cause.
What can we tell customers without a root cause?
State the confirmed impact, the work underway and when the next update will arrive.
When can the incident be closed?
After the affected user action passes, an independent signal agrees and the agreed observation period has ended.